Home > Buy Now > Transformers > 110kV Three Phase On-load Power Transformer
 


Chendian Science & Technologies Co., Ltd
 
icon Single-phase Electronic Watt Hour Meter and Three-phase Electronic Watt Hour Meter
icon Single-phase Watt Hour Meters
icon Three-phase Watt Hour Meters
icon The Transformer
icon Switchgear

line

icon Company Profile

line

 
Contact us
Chendian Science & Technologies Co., Ltd
[China]
Address:
Tiziling,Suxian district, Chenzhou city, Hunan province, China Chenzhou Hunan 423000 China
Phone:
86-0735-2863005
Contact name:
Harry Huang , The Director Of Foreign Trade
Inquire now










Chendian Science & Technologies Co., Ltd



 
The Transformer

110kV Three Phase On-load Power Transformer

Inquire now

110kV Three Phase On-load Power Transformer

Click to enlarge image

 Origin China
 Model Number 110KV transformer
 Brand Name Zhongyan
 Coil Structure Toroidal
 Phase Three
 Usage Power

110kV Three Phase On-load Power Transformer

 

1 General
66kV power transformer are comply with IEC Standards :
IEC 76.11993
IEC 76.21993
IEC 600763:2000
IEC 600765:2000

 

 

2 Model and Designation

 

IP Level (generally omitted, THmoist heat, TAdry heat)

HV Rated Voltage(KV)
Rated Capacity KVA
Design No.9.10
Method of Voltage RegulationNVTC omitted, Z-OLTC)

Conductor Material (Copper omitted, L-aluminum)

Winding Numbers (twowinding omitted, Sthreewinding, FSplit transformer)

Oil Circulation Mode (Natural circulation omitted, P-forced circulation)

Cooling Method
(Jself cooling omitted), F-0i1-immersed forced air cooling , Swater cooling)

Phase (Dsingle phase, S-three phases)

 

3 Service condition

3.1 Type: Outdoor used
3.2 Environment temperature: Maximum temperature + 40 ,Minimum Temperature -30

3.3 Altitude: = 1 000m ( In case of above 1000m, temperature rise should be amended)

3.4 Relative Humidity≤90% [25]
3.5 Installation site: Without corrosive gas and obvious dirt

 

4 110kV Main parameter of the three-phase on-load power transformer

4.5 6300KVA∼63000KVA two-winding transformer (LV is 35KV) with NVTC
Rated capacity KVA Rated ration and regulation range   No load Impedance Voltage% No load losses KW (9) On load losses KW (9) No load losses KW (10) On load losses KW (10)  
HV Regulation range % LV Vector group Current    
%    
6300           1.05   10.3 39.6 9.2 37.4  
8000           1.05   12.4 47.7 11.1 45.1  
10000           0.98   14.4 55.8 12.9 52.7  
12500           0.98   16.9 66.6 15.1 62.9  
16000   ±8×1.25% 6.3,6.6,10.5,11 YNd11 0.91 10.5 20.2 81.9 18.1 77.4  
20000 110,121 ±2×2.5% 35,38.5 YNd12 0.91   23.9 99 21.4 93.5  
25000           0.84   28.1 116.1 25.2 110  
31500           0.84   33.3 140.4 30 132.6  
40000           0.77   39.5 164.7 35.4 155.6  
50000           0.77   46.4 204.3 41.5 193  
63000           0.7   54.9 245.7 49.1 232.1  

 

 

 

 

5 Browsing before order
Please provide the following Information for your order :
Product typerated capacitysystem voltagevoltage groupconnection symbol

short circuit impedanceon-load lossno-load lossno-load currentrated frequency

cooling methodaltitudeenvironment and so on.



  Packaging wooden case
  Delivery lead time 40 Days
  Minimum order 1 piece
  Supply ability 1,500 for one year

Inquire now